Pfaff 1540 User Manual
Page 55

53
28. Adjustment of the stop for the left needle position on Pfaff 1540
Requirement:
When all push buttons are switched off, the needle must be approx. 0.2 mm further left than the widest
zigzag stitch.
The needle must not touch the needle plate.
Check:
z
Set stitch width adjustment dial to "5".
z
Set needle position adjustment dial to "center".
z
Press the zigzag stitch button.
z
Rotate the handwheel until the needle moves downward on the left side and is at a position of roughly
1 mm above the needle plate (fig. 56).
z
Press the button for the buttonhole bartack.
The needle should now move approximately 0.2 mm to the left.
Adjustment:
z
Set stitch width adjustment dial to "5".
z
Set needle position adjustment dial to "center".
z
Press the zigzag stitch button.
z
Loosen screw 84 (fig. 38).
z
Push stop 85 to a position 0.2 mm from the crank 90.
z
Tighten screw 84.
Cross-check:
z
Press the zigzag stitch button and the button for the buttonhole bartack alternately and check whether
the needle moves by approx. 0.2 mm without touching the needle plate.