beautypg.com

Paradyne ACCULINK 3172 User Manual

Page 8

background image

6

Port LB:

Disab

Port-initiated Loopbacks, allows Loopbacks to
be initiated through the port by the external
DTE.

DTLB

DCLB

Both

All Ones:

Disab

All ones sent to network (DTE) E1 when DTR
or RTS interrupted.

DTR

RTS

Both

Rcv RAI:
(Action on Received
Remote Alarm
Indication)

None

Data port remains enabled, or is disabled, on
receiving RAI on the network interface.

Halt

Tx Clock:

Int

Selects whether the transmitted data clock is
internal (TXC) or external (XTXC).

Ext

InvertTxC:
(Invert Tx Clock)

Enab

Selects phase inversion of the transmit clock
(TXC).

Disab

InvertData:

Enab

Allows the data on the port to be inverted.

Disab

EDL:

Enab

Specifies whether the Embedded Data Link is
enabled.

Disab

Err Rate:
(Excessive Error
Rate)

10E-4

Selects the error rate threshold for Excessive
Error Rate Alarm.

10E-5

10E-6

10E-7

10E-8

10E-9

Table 2. Port Configuration Options (2 of 3)

Option

Factory

Comments/Description

This manual is related to the following products: