Paradyne ACCULINK 3172 User Manual
Page 8
6
Port LB:
Disab
Port-initiated Loopbacks, allows Loopbacks to
be initiated through the port by the external
DTE.
DTLB
DCLB
Both
All Ones:
Disab
All ones sent to network (DTE) E1 when DTR
or RTS interrupted.
DTR
RTS
Both
Rcv RAI:
(Action on Received
Remote Alarm
Indication)
None
Data port remains enabled, or is disabled, on
receiving RAI on the network interface.
Halt
Tx Clock:
Int
Selects whether the transmitted data clock is
internal (TXC) or external (XTXC).
Ext
InvertTxC:
(Invert Tx Clock)
Enab
Selects phase inversion of the transmit clock
(TXC).
Disab
InvertData:
Enab
Allows the data on the port to be inverted.
Disab
EDL:
Enab
Specifies whether the Embedded Data Link is
enabled.
Disab
Err Rate:
(Excessive Error
Rate)
10E-4
Selects the error rate threshold for Excessive
Error Rate Alarm.
10E-5
10E-6
10E-7
10E-8
10E-9
Table 2. Port Configuration Options (2 of 3)
Option
Factory
Comments/Description