beautypg.com

23 features – PACKARD BELL MH4000 User Manual

Page 38

background image

2-23

Features

Figure 2-8. Mechanical Locks and Monitoring

POWER

STATUS

DISK

B

Left

Right

A

C

D

A

Front panel
key lock

Key lock the short front panel door to prevent access to the
power and reset switches. This lock also secures the right-
hand door.

B

Location of
internal
intrusion
alarm switch

The intrusion alarm switch is present on the SCSI drive bay
door. The switch opens when the drive bay door is opened. An
intrusion alarm signal is transmitted to the system board,
where server management software processes the signal for
security.

C

Location of two
internal power
inter-lock
alarm switches

The two power inter-lock switches are present on the sides of
the chassis. The switch opens when the side doors are opened.
a power inter-lock signal is transmitted to the system board
controlling a power shut down to the system for safety

D

Padlock loops

Secure the side covers by using padlocks (not provided). The

top cover cannot be removed until the side covers have been
removed.

Environmental
sensors

(Not shown in figure) The system contains sensors to monitor
temperature, voltage, and fan failure.