3

Table 1. Model 3550 DSU Switch Settings

Switch Position

Switch Setting

Function

S1 1

ON

(default)

Permissive V.32 DBM transmit output level
of –9 dBm

S1-1

Off

Programmable V.32 DBM transmit level
between –12 dBm and 0 dBm

S1 2

ON

Frame ground (FG) connected to signal
ground (SG)

S1-2

Off

(default)

FG connected to SG through 100 ohm
resistor

ON is to the rear as you face the front of the DSU.
Off is to the front.