Table 3. Model 3551 DSU Jumper Straps

Strap

Designa-

tion

State of

Jumper

Strap

Function

J12

Left

V.35 Test Mode Indication:

Left — Enables V.35 Test Mode Indication (Pins 1 and
2). This is the factory default.

Right — Disables V.35 Test Mode Indication (Pins 2
and 3).

J13

Left

EIA-232-D Test Mode Indication:

Left

— Enables EIA-232-D Test Mode Indication

(Pins 1 and 2).

This is the factory default.

Right

— Disables EIA-232-D Test Mode Indication

(Pins 2 and 3).

J20

Left

Alarm Monitoring (used with the – 48 Vdc Central Office
Power Unit):

Left

— Disables the – 48 Vdc alarm monitoring

function (Pins 1 and 2). This is the factory default.

Right

— Enables the – 48 Vdc alarm monitoring

function (Pins 2 and 3); the NMS adapter cable is
being used for alarm monitoring.

J21

Right

Alarm Monitoring (used with the – 48 Vdc Central Office
Power Unit):

Left — Enables control of alarm monitoring via the
NMS adapter cable (Pins 1 and 2); the NMS adapter
cable is being used for alarm monitoring.

Right

— Disables control of alarm monitoring via the

NMS adapter cable (Pins 2 and 3); a standard
EIA-232 cable or the NMS adapter cable is being
used for the diagnostic channel. This is the factory
default.