Paradyne 3551 User Manual
Page 13
11
Table 3. Model 3551 DSU Jumper Straps
Strap
Designa-
tion
State of
Jumper
Strap
Function
J12
Left
V.35 Test Mode Indication:
Left — Enables V.35 Test Mode Indication (Pins 1 and
2). This is the factory default.
Right — Disables V.35 Test Mode Indication (Pins 2
and 3).
J13
Left
EIA-232-D Test Mode Indication:
Left
— Enables EIA-232-D Test Mode Indication
(Pins 1 and 2).
This is the factory default.
Right
— Disables EIA-232-D Test Mode Indication
(Pins 2 and 3).
J20
Left
Alarm Monitoring (used with the – 48 Vdc Central Office
Power Unit):
Left
— Disables the – 48 Vdc alarm monitoring
function (Pins 1 and 2). This is the factory default.
Right
— Enables the – 48 Vdc alarm monitoring
function (Pins 2 and 3); the NMS adapter cable is
being used for alarm monitoring.
J21
Right
Alarm Monitoring (used with the – 48 Vdc Central Office
Power Unit):
Left — Enables control of alarm monitoring via the
NMS adapter cable (Pins 1 and 2); the NMS adapter
cable is being used for alarm monitoring.
Right
— Disables control of alarm monitoring via the
NMS adapter cable (Pins 2 and 3); a standard
EIA-232 cable or the NMS adapter cable is being
used for the diagnostic channel. This is the factory
default.