9

Connecting the Model 3550 DSU’s Port 2

For the EIA-232 cable, install as described above.

For the V.35 cable, install the V.35 Interconnect Cable, then the V.35 DTE cable as
follows.

"

Procedure

1. Reconfigure the port to match the interface, V.35 in this example.

2. Connect the 25-pin plug end of the V.35 Interconnect Cable (Feature Number

3000-F1-510) to Port 2. Tighten the holding screws.

3. Connect the plug end of the 34-pin V.35 DTE cable to the other end of the V.35

Interconnect Cable. Tighten the holding screws.

4. Connect the other end of the DTE cable to the appropriate port on the computer or

DTE. Tighten the holding screws.

Changing the Model 3551 DSU Hardware Straps

The Model 3551 DSU has several hardware straps that control the permissive or
programmable connection when a DBM is installed, the Test Mode Indication leads, and
the external interface leads (used with a – 48 Vdc Central Office Power Unit).

Refer to the following figure to locate the switch and jumper locations. If a DBM is
installed, refer to Table 2 to determine which switch needs to be changed, if any. Refer
to Table 3 to determine whether these jumper straps need to be changed.

P7

Faceplate

99-16245

Test Mode

Indication Jumpers

(Shown Enabled)

J13
J12

Rear

Top

J21

–48 Vdc Alarm

Monitoring

(Shown Disabled)

J20

Switch 1