Watchdog timer, Feed sequence – Philips P89LPC903 User Manual
Page 84
Philips Semiconductors
User’s Manual - Preliminary -
P89LPC901/902/903
WATCHDOG TIMER
2003 Dec 8
84
Figure 12-1: Watchdog Prescaler
Feed Sequence
The watchdog timer control register and the 8-bit down counter (Figure 12-3) are not directly loaded by the user. The user writes
to the WDCON and the WDL SFRs. At the end of a feed sequence, the values in the WDCON and WDL SFRs are loaded to the
control register and the 8-bit down counter. Before the feed sequence, any new values written to these two SFRs will not take
effect. To avoid a watchdog reset, the watchdog timer needs to be fed (via a special sequence of software action called the feed
sequence) prior to reaching an underflow.
To feed the watchdog, two write instructions must be sequentially executed successfully. Between the two write instructions, SFR
reads are allowed, but writes are not allowed. The instructions should move A5H to the WFEED1 register and then 5AH to the
WFEED2 register. An incorrect feed sequence will cause an immediate watchdog reset. The program sequence to feed the
watchdog timer is as follows:
CLR
EA
; disable interrupt
MOV
WFEED1,#0A5h
; do watchdog feed part 1
MOV
WFEED2,#05Ah
; do watchdog feed part 2
SETB
EA
; enable interrupt
This sequence assumes that the P89LPC901/902/903 interrupt system is enabled and there is a possibility of an interrupt request
occuring during the feed sequence. If an interrupt was allowed to be serviced and the service routine contained any SFR writes,
it would trigger a watchdog reset. If it is known that no interrupt could occur during the feed sequence, the instructions to disable
and re-enable interrupts may be removed.
In watchdog mode (WDTE = 1), writing the WDCON register must be IMMEDIATELY followed by a feed sequence to load the
WDL to the 8-bit down counter, and the WDCON to the shadow register. If writing to the WDCON register is not immediately
followed by the feed sequence, a watchdog reset will occur.
For example: setting WDRUN = 1:
MOV
ACC,WDCON
; get WDCON
SETB
ACC.2
; set WD_RUN=1
MOV
WDL,#0FFh
; New count to be loaded to 8-bit down counter
CLR
EA
; disable interrupt
MOV
WDCON,ACC
; write back to WDCON (after the watchdog is enabled, a feed must occur
; immediately)
PRE2
PRE1
PRE0
DECODE
ч2
ч2
ч2
ч2
ч2
ч2
ч2
ч32
ч64
ч128
ч256
ч512
ч1024
ч2048
ч4096
000
001
010
011
100
101
110
111
TO
WATCHDOG
DOWN
COUNTER
(after one
prescaler
count delay
Watchdog
Oscillator
WDCLK after a
watchdog feed
sequence
PCLK
ч32