beautypg.com

Troubleshooting & repair, Test for contact continuity, Input contactor test (continued) – Lincoln Electric MULTI-SOURCE SVM155-A User Manual

Page 43: Top view test points test points test points

background image

F-15

F-15

TROUBLESHOOTING & REPAIR

MULTI-SOURCE

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

T3

T2

T1

U

V

W

TOP VIEW

Test Points

Test Points

Test Points

TEST FOR CONTACT
CONTINUITY

1. Disconnect the main input supply power to

the machine.

2. Remove the two leads connected to the

input contactor coil, #240 and #241. See
Figure F.3
for location.

3. Using the external 120VAC supply, apply

120VAC to the leads of the input contactor
coil. If the contactor does NOT activate,
the input contactor is faulty. Replace the
input contactor.

4. With the contactor activated, check the

continuity across the contacts. (Zero ohms
or very low resistance is normal.) See

Figure F.4. If the resistance is high, the
input contactor is faulty. Replace the input
contactor.

5. When the contactor is NOT activated, the

resistance should be infinite or very high
across the contacts. If the resistance is
low, the input contactor is faulty. Replace
the input contactor . See Input Contactor
Removal and Replacement Procedure.

6. Reconnect any leads previously removed.

Replace any cable ties and loom previous-
ly removed. Replace the roof and left case
side.

FIGURE F.4. INPUT CONTACTOR TEST CONNECTIONS

INPUT CONTACTOR TEST (Continued)