Installation, Technical specifications - invertec v250-s, Physical dimensions three phase single phase – Lincoln Electric INVERTEC V250-S User Manual
Page 8: Input recommended input wire and fuse sizes

A-2
INSTALLATION
INVERTEC V250-S
A-2
Height
Width
Depth
Weight
15.0 in.
9.1 in.
19.7 in.
36 lbs.
381 mm
231 mm
500 mm
17 Kg
PHYSICAL DIMENSIONS
THREE PHASE
SINGLE PHASE
Standard
Input Current
Voltage
at Rated Output
Model
208/230/460 34/32/16
60Hz
200/220/400/440 35/33/18/17
50/60
Hz
Volts at
Duty Cycle
(1)
Amps
Rated Amps
Model
35% Duty Cycle
250
30
60Hz
60% Duty Cycle
200
28-32
60Hz
100% Duty Cycle
165
26.5
60Hz
35% Duty Cycle
250
28†-30
50/60Hz
60% Duty Cycle
200
29-32
50/60Hz
100% Duty Cycle
165
26.5
50/60Hz
Welding
Constant Open
Current Range
Circuit Voltage
1-250 Amps
65-80 VDC
Standard
Input Current
Voltage
at Rated Output
Model
208/230/460 60Hz
59/57/29
60Hz
200/220/400/440 50/60 Hz
58/58/30/30
50/60 Hz
Volts at
Duty Cycle
(1)
Amps
Rated Amps
Model
35% Duty Cycle
250
27†-30
60Hz
60% Duty Cycle
200
28-32
60Hz
100% Duty Cycle
165
26.5
60Hz
35% Duty Cycle
250
26†-30
50/60Hz
60% Duty Cycle
200
28-32
50/60Hz
100% Duty Cycle
165
26.5
50/60Hz
Welding
Constant Open
Current Range
Circuit Voltage
1-250 Amps
65-80 VDC
INPUT
RECOMMENDED INPUT WIRE AND FUSE SIZES
Type 75°C
Type 75°C
Copper
Fuse
Input
Copper
Ground
(Superlag)
Ampere
Wire in
Wire in
Input
or
Rating
Conduit
Conduit
Voltage
Breaker
on
AWG (IEC)
AWG (IEC)
Frequency
(2)
Size
Nameplate
Sizes
Sizes
208/60
50
34
10 (6mm
2
)
10 (6mm
2
)
230/60
50
32
10(6mm
2
)
10 (6mm
2
)
460/60
30
16
10 (6mm
2
)
10 (6mm
2
)
200/50/60
50
35
10 (6mm
2
)
10 (6mm
2
)
220/50/60
50
33
10 (6mm
2
)
10 (6mm
2
)
400/50/60
30
18
10 (6mm
2
)
10 (6mm
2
)
440/50/60
30
17
10 (6mm
2
)
10 (6mm
2
)
Type 75°C
Type 75°C
Copper
Fuse
Input
Copper
Ground
(Superlag)
Ampere
Wire in
Wire in
Input
or
Rating
Conduit
Conduit
Voltage
Breaker
on
AWG (IEC)
AWG (IEC)
Frequency
(2)
Size
Nameplate
Sizes
Sizes
208/60
(3)
80
59
8 (10mm
2
)
10 (6mm
2
)
230/60
(3)
80
57
8 (10mm
2
)
10 (6mm
2
)
460/60
40
29
10 (6mm
2
)
10 (6mm
2
)
200/50/60
80
58
8 (16mm
2
)
10 (6mm
2
)
220/50/60
80
58
8 (16mm
2
)
10 (6mm
2
)
400/50/60
40
30
10 (6mm
2
)
10 (6mm
2
)
440/50/60
40
30
10 (6mm
2
)
10 (6mm
2
)
THREE PHASE
SINGLE PHASE
THREE PHASE
SINGLE PHASE
THREE PHASE
SINGLE PHASE
OUTPUT
RATED OUTPUT
(1)
Based on a 10 min. period.
(2) Input voltage must be within ±10% of rated value.
(3)
For 1 phase use on 208 or 230 VAC input with output usage above 175A/60% or 200A/35%, the #10 input line cord supplied with the unit should be changed to a
#8 or larger conductor cord.
(†) 200 & 208VAC input may not meet NEMA/IEC specifications at 250 Amps.
Technical Specifications - Invertec V250-S