Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric
Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

CAUTION

OUTPUT PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

No output - Main input fuses open,
indicating excessive current draw.

The machine operates normally
when connected for 200 - 230VAC
input. There is no output when the
machine is connected to 380VAC or
higher.

1. Inspect input leads for possible

shorts or grounds or mis-connec-
tions.

2. Install new fuses and reapply

power. If fuses open again, con-
sult a Lincoln Authorized Field
Service Facility.

1. Check the input voltage and input

voltage reconnect procedures.
See

Installation Section of this

manual.

1. Inspect interior of machine for

physical signs of electrical and
heat damage. Replace any dam-
aged components after conduct-
ing the following tests.

2. Perform the

Input Rectifier Test.

3. Perform

Power Board

Resistance Test.

4. Check the reconnect switch and

associated leads for “shorts” or
faulty wiring.

1. Perform the

Capacitor Balance

Test.

2. Perform the

Protection Circuit

Test.

3. Perform the

Auxiliary

Transformer Test.

4. Perform the

Power Board

Resistance Test.