TYPE 18—National Synchronous Wired

For a list of Type 18 clocks, see the chart on the first page of this appendix.

Relay K5 is normally operated to power the clock run motors. Each hour from HH:00:00
to HH:00:28, relay K6 is operated to power the clock correction coils for 28 seconds and
cause hourly corrections. Every 12 hours, from 6:00:00 to 6:27:27, relay K6 is again op-
erated to power the clock correction coils for 27 minutes, causing 12-hour correction.

Manual clock corrections can be issued from the master during any even-numbered
minute except 00.

B-24

24A715/24A715M Master Clock Installation Manual

1

2

3

4

5

6

7

8

CLK1 OR CLK2

x

x

x

x

RELAY

K6 (K8)

RELAY

K5 (K7)

I

I

MASTER CLOCK

FIELD CONNECTIONS

X = Normally open contact

I = Normally closed contact

SOURCE

POWER

10 ASB MAX.

CORRECTION COIL

RUN MOTOR

RETURN

1 = V250LA4 MOV or equal

1

1

1

Figure B-21

National Synchronous Wired