TYPE 04—Standard Electric Time AR-2A Two-Wire, Dual Voltage
Each minute, from 58 seconds to 00 seconds, a low-voltage pulse (24Vdc) is transmitted.
The secondary clocks receive the pulses until the 59th minute. At this time, from 50 sec-
onds to 00 seconds, a higher voltage pulse (48Vdc) is required to advance to the hour.
Manual clock advances and daylight saving advances cause the master clock to transmit
62 pulses (one second ON and one second OFF at 0.5Hz), all at 24Vdc. Normal minute
pulses are inhibited during these pulses.