beautypg.com

Appendix, Technical appendix – Listen Technologies Central Unit CU 6010 User Manual

Page 36

background image

Danish Interpretation Systems

User Manual

Manual 01 18 04438

36

Appendix

Technical appendix

Cabling

CAT5

The DCS 6000 system uses CAT5, CAT5e or
CAT6 FTP or STP cables with screened RJ45
connectors.

EIA 568-B wiring shall be used.

It is important to use only FTP or STP
(screened) cables and screened RJ45 connectors
and not UTP cable, which is unscreened.

How to wire a CAT5 (EIA 568-B) Cable:

Pin Function

Connector #1 Connector #2

1

In-going +

ORG/WHT

ORG/WHT

2

In-going -

ORG

ORG

3

+48V

GRN/WHT

GRN/WHT

4

0V

BLU

BLU

5

0V

BLU/WHT

BLU/WHT

6

+48V

GRN

GRN

7

Outgoing -

BRN/WHT

BRN/WHT

8

Outgoing + BRN

BRN

Note. If other colour codes are used then the four

pairs are connected as follows:

Pair 1:

Pin 1 & 2

Pair 2:

Pin 3 & 6

Pair 3:

Pin 4 & 5

Pair 4:

Pin 7 & 8

The phase of the pairs must be correct and

the wiring spec. as stated in CAT5 (EIA
568-B) have to be followed.

Note: CAT6 cables can normally only be
terminated in sockets (female) and not in cable
plugs.

CAT6 can thus only be used for longer cable draws
terminating in wall outlets or patch panels.

RS 232 Serial connection

Pin

RS232 on CU

6005/6010/6011

D9S

Pin

RS232 on PC

D9P

1

*

1

DCD

2

TxD

2

RxD

3

RxD

3

TxD

4

*

4

DTR

5

0V

5

0V

6

*

6

DSR

7

RTS

7

CTS

8

CTS

8

RTS

9

9

RI

Connect all pins in the connectors: Pin 1 to Pin 1,
Pin 2 to Pin 2, Pin 3 to Pin 3 and so on.

*

Pin 1, 4 and 6 are connected together inside
the CU 6005/6010/6011.

RS 422 Serial connection

Pin

RS422 on CU

6005/6010/6011

D9P

Pin

RS422 on PC

1

RXD+(B)

1

2

RXD-(A)

2

3

TXD-(A)

3

4

TXD+(B)

4

5

0V

5

6

RTS-(A)

6

7

RTS+(B)

7

8

CTS+(B)

8

9

CTS-(A)

9

Note. There is no standard for the pin layout of

the RS422. Please consult the manual for
the RS422 card in your PC or control
system.

This manual is related to the following products: