beautypg.com

Listen Technologies Central Unit CU 6010 User Manual

Page 10

background image

Danish Interpretation Systems

User Manual

Manual 01 18 04438

10

User Controls, indications & connectors

Front plate layout

The front plate layout of the CU 6010 Central Unit consists of a large illuminated LCD display and 8 buttons for
setting up/controlling the system:

Details of display

-Audio Control
-Delegate setup
-Interpreter setup
-Units info

MENU

ENTER

Front plate controls

The CU 6010 Central unit features the following
controls and display:

Power switch

Switches power on to the whole system. When
power is switched ON at the CU 6010 any
connected

EX

6010

Extension

Units

will

automatically be powered up. An indication in the
switch is lighting, when power is switched ON

Fault LED

This indication lights up, if the internal power
supply is malfunctioning i.e. because of overheating
or overload of a chain.

The Fault LED will always light up some seconds
after the unit is switched on caused by the delayed
switching on of the four supplies.

As a warning the light is flashing at an internal
temperature above 45

°

C. At a temperature above

55

°

C or if one of the DCS-LAN outputs is

supplying no voltage, the LED is lighting
constantly.

Please note that the maximum ambient temperature
for the CU 6010 is 40 deg. Celsius.

LCD Display

This display is used for information purposes and
set-up purposes.

This manual is related to the following products: