Maximum number of units to be connected

The following table shows the maximum number of
units, which can be connected to each of the four
outputs

(A1, A2, B1 or B2)

on a CU 6010/6011

Central Unit or on each output on an EX 6010
Extension Unit or on the output of a PS 6000..

CM/DM 60x0P Chairman/Delegate Units – CU 6010/6011

Length of Feeding Cable

Type CAT5 AWG24

Length of inter connecting

Cable, Type CAT5 AWG24

Total cable length

Max. number of CM/DM

60x0P pr output

10 m

1 m

51 m

42

30 m

1 m

67 m

38

50 m

1 m

83 m

34

100 m

1 m

122 m

23

150 m

1 m

165 m

16

10 m

2 m

88 m

40

30 m

2 m

98 m

35

50 m

2 m

108 m

30

100 m

2 m

140 m

21

150 m

2 m

178 m

15

CM/DM 60x0P Chairman/Delegate Units – CU 6005

The following table shows the maximum number of
units, which can be connected to the two outputs
(A1 and A2) simultaneously on a CU 6005 in total

If only one chain is used the information in the
above table must be used.

Length of Feeding Cable

Type CAT5 AWG24

Length of inter connecting

Cable, Type CAT5 AWG24

Total cable length

Max. number of CM/DM

60x0P for both outputs

10 m

1 m

2x32 m

2x23

30 m

1 m

2x51 m

2x22

50 m

1 m

2x70 m

2x21

100 m

1 m

2x117 m

2x18

150 m

1 m

2x164 m

2x15

10 m

2 m

2x54 m

2x23

30 m

2 m

2x72 m

2x22

50 m

2 m

2x88 m

2x20

100 m

2 m

2x132 m

2x17

150 m

2 m

2x176 m

2x14

CM/DM 60x0P Chairman/Delegate Units & JB 6002 Junction Box – CU 6010/6011

This configuration shows two CM/DM 60x0P
Delegate/Chairman Units connected to one JB 6002
Junction Box with 3m cables between each JB
6002.

Maximum 5 m cable from JB 6002 to CM/DM
60x0 and maximum one CM/DM 60x0 on each
output of JB 6002.

This manual is related to the following products: