Length of Feeding Cable,

Type CAT5 AWG24

Length of Cable between each

JB 6002, Type CAT5 AWG24

Total cable

length

Number of

JB 6002

Max. number of

DM 60x0

10 m

3 m

61 m

18

36

30 m

3 m

75 m

16

32

50 m

3 m

89 m

14

28

100 m

3 m

127 m

10

20

150 m

3 m

168 m

7

14

CM/DM 6060F/6510F Chairman/Delegate Units – CU 6010/6011

The following table shows the maximum number of
units, which can be connected to each of the four
outputs

(A1, A2, B1 or B2)

on a CU 6010/6011

Central Unit or on each output on an EX 6010
Extension Unit or on the output of a PS 6000.

Length of Feeding Cable

Type CAT5 AWG24

Length of inter connecting

Cable, Type CAT5 AWG24

Total cable length

Max. number of

CM/DM 60x0 pr output

10 m

1 m

39 m

30

30 m

1 m

56 m

27

50 m

1 m

73 m

24

100 m

1 m

115 m

16

150 m

1 m

160 m

11

10 m

2 m

64 m

28

30 m

2 m

78 m

25

50 m

2 m

94 m

23

100 m

2 m

130 m

16

150 m

2 m

170 m

11

CM/DM 6560F Chairman/Delegate Units – CU 6010/6011

The following table shows the maximum number of
units, which can be connected to each of the four
outputs

(A1, A2, B1 or B2)

on a CU 6010/6011

Central Unit or on each output on an EX 6010
Extension Unit or on the output of a PS 6000.

Length of Feeding Cable

Type CAT5 AWG24

Length of inter-connecting

Cable, Type CAT5 AWG24

Total cable length

Max. number of CM/DM

60x0 pr output

10 m

1 m

35 m

27

30 m

1 m

53 m

24

50 m

1 m

70 m

21

100 m

1 m

113 m

14

150 m

1 m

159 m

10

10 m

2 m

58 m

25

30 m

2 m

72 m

22

50 m

2 m

88 m

20

100 m

2 m

126 m

14

150 m

2 m

166 m