Operation – Lincoln Electric POWER FEED SVM185-A User Manual
Page 27
OPERATION
B-9
B-9
POWER FEED® 25M
NON-SYNERGIC GMAW AND FCAW
WELDING
(See Figure B.4)
Non-synergic GMAW and FCAW welding mimics the
welding controls of traditional welding power sources.
Voltage and WFS are set as independent variables.
Three non-synergic welding modes are available.
Description
Mode
Used for:
GMAW, Standard CV
5
Best for traditional
MIG welding.
GMAW, Power
40
Specialized mode
for short arc weld-
ing and CV alu-
minum welding.
FCAW
6
Best for cored
electrodes, such
as Innershield™
and Outershield™.
K2368-1
Power Wave 355M
1
K2202-1
Power Wave 455M
K2203-1
Power Wave 455M/STT
K2230-1
Power Feed 10M, Bench Model
K2234-1
Power Feed 10M Dual, Bench Model
K2536-1
Power Feed 25M
2
KP1696-xx,
Drive Roll Kit, 2 Roll Feeder
KP1697-xx
KP1505-xx,
Drive Roll Kit, 4 Roll Feeder
KP1507-xx
3
K1543-xx
Digital Control Cable
4
K1842-xx
Weld Power Cable, Lug to Lug
K910-xx
Ground Clamp
5
See Magnum
MIG gun
Literature
Deluxe Regulator for Mixed
6
K586-1
Shielding Gases
Shielding Gas Hose
6
4
3
2
5
1
FIGURE B.4