1 2 - 1 6 - 9 3

M 1 7 2 1 4

ELECTRODE CABLE

TO WORK

ELECTRODE

14 PIN
AMPHENOL

TO WORK

TO WIRE FEED UNIT

CAUTION :

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE

DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN
THE ENGINE WELDER OPERATING MANUAL.

N.B. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE

APPLICATIONS. SEE OPERATING MANUAL.

N.A. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR SWITCH TO A CV POSITION.

N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITIION.

AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE

PLACE WELDER TERMINALS SWITCH TO "REMOTELY CONTROLLED" POSITION.

N.D. PLACE IDLER SWITCH IN "AUTO" OR "HIGH" IDLE POSITION AS DESIRED.

RANGER 9 / LN-25 WITH 42 VOLT REMOTE OUTPUT
CONTROL MODULE CONNECTION DIAGRAM

K626-XX INPUT CABLE ASSEMBLY

TO LN-25 INPUT
CABLE PLUG

WARNING

Do not operate with panels open.
Disconnect NEGATIVE (-) BATTERY LEAD
before servicing.

Do not touch electrically live parts.

Keep guards in place.
Keep away from moving parts.
Only qualified personnel should install,use
or service this equipment.

– 34 –

4-19-96D

S20909

WARNING

can kill

ELECTRIC SHOCK

-

+

POWER SOURCE

6-PIN

PLUG

ELECTRODE LEAD

WORK SENSE LEAD

*

*

BYPASS

CAPACITOR

KIT

*

HI-FREQ KIT

INPUT POWER

*

5-PIN

PLUG

K915-1

AMPTROL

ADAPTER

6-SOCKET

RECEPTACLE

K963 HAND

AMPTROL

K870 FOOT

AMPTROL

OR

*

KIT FOR CONNECTION INFORMATION.

SEE INSTRUCTIONS INCLUDED WITH HI-FREQ

THIS ADAPTER ALLOWS AN AMPTROL TO OPERATE A

OUTPUT CURRENT OF A LINCOLN POWER SOURCE.

(THE POWER SOURCE MUST BE EQUIPPED WITH A

6-PIN REMOTE CONTROL AMPHENOL CONNECTOR.)

SEE THE HI-FREQ KIT AND POWER SOURCE INSTRUC-

AND CONTROL SETTINGS.

TION MANUAL FOR INFORMATION ON PROPER SWITCH

OF THE WELDING POWER SOURCE "OFF"

TURN THE ENGINE OR POWER SWITCH

BEFORE CONNECTING OR DISCONNECTING

PLUGS TO WELDING POWER SOURCE.

K915-1 AMPTROL ADAPTER FOR K799 HI-FREQ KITS

K799 HI-FREQ KIT WHILE REMOTELY CONTROLLING THE

K799 HI-FREQ KIT