Warning, Ranger 9 / ln-25 across the arc connection diagram – Lincoln Electric RANGER IM511-D User Manual

Page 33

background image

– 31 –

1 2 - 1 6 - 9 3

M 1 7 0 9 0

ELECTRODE CABLE

LN-25

WIRE FEEDER

REMOTE CONTROL

TO WORK

ELECTRODE

N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.

TO WORK

WORK CLIP LEAD

WARNING

Do not operate with panels open.
Disconnect NEGATIVE (-) BATTERY LEAD
before servicing.

Do not touch electrically live parts.

Keep guards in place.
Keep away from moving parts.
Only qualified personnel should install,use
or service this equipment.

TO WORK

6 PIN
AMPHENOL

N.B. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR
SWITCH TO A CV POSITION.

N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE OUTPUT CONTROL SWITCH
IN "OUTPUT CONTROL REMOTE" POSITION.

RANGER 9 / LN-25 ACROSS THE ARC CONNECTION DIAGRAM

14 PIN
AMPHENOL

N.D. WELDING TERMINALS SWITCH MUST BE PLACED IN "ALWAYS ON" POSITION.

OPTIONAL K444-1

1 2 - 1 6 - 9 3

M 1 7 0 9 1

SPARE

82

81

42

41

31

32

2

4

21

GND

75

76

77

31

32

2

4

21

GND

K867 UNIVERSAL

ADAPTER PLUG

75

76

77

GREEN

T O W O R K

E L E C T R O D E

TO WORK

1 4 P I N
A M P H E N O L

CAUTION :

N.D.

N.E.

ELECTRODE CABLE
TO WIRE FEED UNIT

LN-7
WIRE
FEEDER

K291 OR K404
INPUT CABLE

K775 OPTIONAL
REMOTE CONTROL

N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.

N.D. INSULATE EACH UNUSED LEAD INDIVIDUALLY.
N.E. SPLICE LEADS AND INSULATE.

N.B. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR SWITCH TO A CV POSITION.

N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITION.

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE

DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN

THE ENGINE WELDER OPERATING MANUAL.

AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE

RANGER 9 / K867 / K775 / LN-7 CONNECTION DIAGRAM

PLACE WELDING TERMINALS SWITCH TO "REMOTELY CONTROLLED" POSITION.

N.F. PLACE IDLER SWITCH IN "HIGH" IDLE POSITION.

WARNING

Do not operate with panels open.
Disconnect NEGATIVE (-) BATTERY LEAD
before servicing.

Do not touch electrically live parts.

Keep guards in place.
Keep away from moving parts.
Only qualified personnel should install,use
or service this equipment.