beautypg.com

Mmc 50 system timers – Samsung NX-308 User Manual

Page 117

background image

This MMC is used to adjust individual timers as necessary. All available timers are
described in the TABLE OF TIMERS AND VALUES.

NOTE: Seconds are shown as 'SEC', milliseconds as 'MS', and minutes as 'MIN'.

PROCEDURE

LCD DISPLAY

1. Press [TRANSFER] and dial 50

2. Press [VOLUME (-) or (+)] to select a timer

(e.g. ALM R DUR)

3. Enter new value using KEYPAD

4. Press [TRANSFER] to save and exit

DEFAULT DATA

See TABLE OF TIMERS AND VALUES

RELATED MMC

NONE

TABLE OF TIMERS AND VALUES

DISPLAY

DESCRIPTION

DEFAULT RANGE

ALM R INT

controls the time length between ring attempts

025SEC

250SEC

(Alarm ring

at a station when alarm reminder is set.

interval)

ALM R DUR

controls the length of ring cycle duration when

010SEC 1~250SEC

(Alarm ring

alarm reminder is set at a station.

duration)

ARDL INT

controls the time between attempts after Auto

045SEC 1~250SEC

(Auto Redial

Redial is set 'ON' at a station.

interval)

ARDL RELS

controls the duration of a Ring No Answer

045SEC 1~250SEC

(Auto Redial

condition on an auto-redial number dialed

release time)

before auto redial is canceled.

CBACK NOA

controls the time before the callback is canceled

030SEC

1~250SEC

(Callback no

when a callback detects Ring No Answer

answer time)

CO CO DIS

monitors the duration of an unsupervised

010MIN

1~250MIN

(CO to CO

conference, external call forward, or DISA call.

disconnect

upon expiring, both trunks are disconnected.

time)

DISA F DG

controls how long the system will wait for

025SEC 1~250SEC

dialing to begin the DISA incoming call.

DISA I DG

controls the grace period between dialing valid

025SEC 1~250SEC

digits before dropping the call to DISA user.

DISA RING

controls no answer time for DISA internal calling.

030SEC 1~250SEC

DOOR RELS

controls the duration of time before the door

1500MS

100~

(Door release lock relay deactivates.

2500MS

time)

NX-SERIES

HYBRID KEY SYSTEM

PROGRAMMING SECTION

MMC 50

SYSTEM TIMERS