A-61580 November 2007

Jam and fault
recovery

This section provides recommendations for application logic associated
with scanner jam and fault recovery.

If your scanner is enabled and you are polling when a document jam or
other fault occurs, use the following procedure to restart scanning.

IMPORTANT: Before beginning fault recovery, make sure all the

headers and images have been transferred from the
image buffer to the host system.

When a document jam or other fault occurs, the feeder and the
transport will stop and the scanner will be disabled.

1. When all images have been retrieved from the scanner (image

buffer empty), display the last image retrieved for operator viewing.

2. Use the image header of the last image retrieved to determine the

image address and sequential counter.

3. Use the information above +1 to seed the next image address and

sequential counter before re-enabling the scanner.

4. Instruct the operator to sort through the stack of documents being

scanned to find the document that produced the last successfully
scanned image. They must rescan all of the documents that follow
the last successfully scanned document.

5. Enable the scanner.