Konica Minolta BIZHUB 920 User Manual
Page 88
FIA_SOS.1[1]
For the registration and the change of User BOX password, whether the password is within the
coverage of permitted value along the password rules is judged in MNG.ADM and IA.PASS respect-
ively.
Therefore, FIA_SOS.1[1] is realized by implementing MNG.ADM and IA.PASS.
FIA_SOS.1[2]
For the registration of administrator password and the change of administrator/CE password,
whether the password is within the coverage of permitted value along the password rules is judged in
IA.ADM_ADD and IA.PASS respectively.
Therefore, FIA_SOS.1[2] is realized by implementing IA.ADM_ADD and IA.PASS.
FDP_SOS.1
For the registration of HDD password, FDP_SOS.1 judges whether the password is within the
coverage of permitted value along the password rules in MNG_HDD.
Therefore, FDP_SOS.1 is realized by implementing MNG_HDD.
FIA_AFL.1
In case of the unsuccessful authentication, for the administrator, CE, and general user who owns
User BOX, the next authentication trial is not executed for five seconds in IA.ADM_AUTH, IA.CE_
AUTH, and ACL.USR, to the administrator, CE, and general user who owns User BOX respectively.
Therefore, FIA_AFL.1 is realized by implementing IA.ADM_AUTH, IA.CE_AUTH, and
ACL.USR.
FDP_ACC.1[1]
ACL.USR executes to read out the document data according to Access control policy 1.
Therefore, FDP_ACC.1[1] is realized by implementing ACL.USR.
FDP_ACC.1[2]
MNG.ADM creates the User BOX according to Access control policy 2.
Therefore, FDP_ACC.1[2] is realized by implementing MNG.ADM.
FDP_ACF.1[1]
ACL.USR executes to read out the document data according to Access control policy 1.
Therefore, FDP_ACF.1[1] is realized by implementing ACL.USR.
Copyright© 2005 KONICA MINOLTA BUSINESS TECHNOLOGIES, INC., All Rights Reserved