Access control function – Konica Minolta BIZHUB 920 User Manual
Page 62
Administrator Administrator password, User BOX
password
General user who owns User BOX
User BOX password of his/her own User BOX
For the password entered by the product-related persons,
the permitted value is validated according to the following
rules.
- CE and administrator passwords of 8 characters
- User BOX password of 8 to 64 characters
- Password of English characters, one-byte capital letters,
small letters, and numerals
- Prohibition of the same password with that used one
generation ago
In the validation of permitted value, the administrator is
registered if the rules are obeyed, and it is rejected if not
so.
6.1.2. Access Control Function
The access control function provides the following a group of security functions.
Function title
Specification of security function
TOE security
functional
requirement
ACL.USR
Access rule
and control to
general user
ACL.USR identifies and authorizes the general user who
owns User BOX and limits the operatable coverage for the
general user according to the access rules after he/she is
authenticated to be the valid user.
ACL.USR identifies and authorizes the general user who
owns User BOX by the User BOX identifier and User
BOX password. When the User BOX password is entered,
dummy characters (*) are displayed in stead of the entered
User BOX password.
After the successful identification and authentication, the
following operation is permitted for the document data in
the User BOX shown by the identified and authenticated
User BOX identifier.
FIA_UID.2
FIA_UAU.2
FIA_UAU.7
FIA_AFL.1
FDP_ACC.1[1]
FDP_ACF.1[1]
FPT_RVM.1
Copyright© 2005 KONICA MINOLTA BUSINESS TECHNOLOGIES, INC., All Rights Reserved