beautypg.com

6. control codes used for peripheral units – Star Micronics SP300 User Manual

Page 53

background image

– 49 –

7-6. Control Codes Used for Peripheral Units

FUNCTION

Adjust drive pulse width for peripheral unit 1

CODE

n1 n2
(1B)

H

(07)

H

n1 n2

DEFINITION RANGE

1

n1

127, 1

n2

127 (default setting n1 = n2 = 20)

OUTLINE

Adjusts drive pulse width for peripheral devices requiring
other than standard 200 ms pulse time and delay time
Energizing time = 10

×

n1 (ms)

Delay time = 10

×

n2 (ms)

Executed by , codes.

NOTE

Adjustment is not necessary for standard cash drawers in the
U.S.A. market.

FUNCTION

Deferred drive command for peripheral unit 1

CODE


(07)

H

OUTLINE

Executes drive pulse for peripheral unit 1 (deferred).

FUNCTION

Immediate drive command for peripheral unit 1

CODE


(1C)

H

OUTLINE

Executes drive pulse for peripheral unit 1 (immediate).
This code differs from the code as follows:
When the printer receives an code, the command is
executed immediately. The code is stored in the data
buffer in the same manner as other codes, and executed in the
order in which they are received.

ON

OFF

10

×

n

1 (ms)

10

×

n

2 (ms)

Printing and paper feed
are prohibited.