Instructions for the installer

27

3.3 Regulation for natural gas

The hob has been inspected for G20 (2H) natural gas at a pressure of
20 mbar. To allow the unit to work with this type of gas, perform the same
operations described in paragraph “3.2 Regulation for LPG”, but choose
the nozzles and regulate the primary air for natural gas, as shown in the
following table and in paragraph “3.4 Regulation of primary air”.

Burner

Rated

heating

capacity

(kW)

Natural gas – G20 20 mbar

Nozzle diameter

1/100 mm

Reduced flowrate

(W)

Top with front controls:

Auxiliary

1.05

73

380

Semi rapid

1.65

92

420

Rapid

2.55

115

650

Ultrarapid

3.25

130

1400

Top with side controls:

Auxiliary

1.05

73

380

Semi rapid

1.65

92

450

Rapid

2.55

115

650

Ultrarapid

3.25

130

1400

3.4 Regulation of primary air

Referred to distance “X” in mm.

BURNER

G20

20 mbar

G30/G31

28/37 mbar

Top with front controls:

Auxiliary

2.5

2.5

Semi rapid

1.5

2

Rapid

2.5

2

Ultrarapid

1.5

2.5

Top with side controls:

Auxiliary

3

3

Semi rapid

2

1.7 (*)

Rapid

3

2.5

Ultrarapid

1.7

3 (**)

(*) Semi rapid, rear: 2.5
(**) Ultrarapid, front: 4