A-4 mvds x-1 user's guide – Silex technology Multicast Video Distribution System MVDS X-1 User Manual
Page 76

A-4
MVDS X-1 User's Guide
Parameter name
Description
Value range
Default value
T
X
R
X
H.Position Offset
Save the offset value for H.Position
setting that you may have configured
from LCD menu.
0 - 100
50
* -
H.Width Offset
Save the offset value for H.Width
setting that you may have configured
from LCD menu.
0 - 100
50
* *
H.Period Offset
Save the offset value for H.Period
setting that you may have configured
from LCD menu.
0 - 100
50
* *
H.Back Porch Offset
Save the offset value for H.Back Porch
setting that you may have configured
from LCD menu.
0 - 100
50
- *
V.Position Offset
Save the offset value for V.Position
setting that you may have configured
from LCD menu.
0 - 100
50
* -
V.Width Offset
Save the offset value for V.Width
setting that you may have configured
from LCD menu.
0 - 100
50
* *
V.Period Offset
Save the offset value for V.Period
setting that you may have configured
from LCD menu.
0 - 100
50
* *
V.Back Porch Offset
Save the offset value for V.Back Porch
setting that you may have configured
from LCD menu.
0 - 100
50
- *
PLLGAIN_H
Specify the PLLGAIN VCO Range.
0 : 8-72MHz
1 : 16-144MHz
2 : 16-144MHz
3 : 24-215MHz
1
* -
PLLGAIN_L
Specify the PLLGAIN Charge Pump
Current.
0 - 7
6
* -
PLLDIV
Specify the ADC PLL Divider ratio.
Usually, equivalent to the value of
H.Period minus one.
0 - 65535
1687
* -
CLPDLY
Specify the Clamp Pulse Delay.
0 - 255
8
* -
CLPDUR
Specify the Clamp Pulse width.
0 - 255
32
* -
HSOPW
Specify a pulse width of ADC HSOUT.
0 - 255
96
* -
SYNC_CTRL
Perform a synchronization control.
0 - 255
64
* -
PHASE_CC
Specify the PHASE for image sampling. 0 - 255
0
* -
Baudrate
Specify a baudrate.
300, 600, 1200, 2400, 4800,
9600, 14400, 19200, 38400,
57600, 115200
19200
* *
Bit length
Specify a bit length.
8, 7
8
* *
Stop bit
Specify a stop bit.
1, 2
1
* *
Parity
Specify a parity check method.
None, Odd, Even
None
* *
Flow control
Specify a flow control method.
None, XON/XOFF, RTS/CTS
None
* *
Data Timeout
Specify a serial input timeout by
millisecond.
50-1000
100
* *
Buffer level
Specify the number of buffer for
retransmission.
16 - 64
64
* *
Node List Method
Specify a node search method.
Dynamic, Static
Dynamic
* *
Static Node 0 - 7
Specify an IP address for node when
Node List Method is set to Static.
IP Address
0.0.0.0
* *