Setting, Power management, Slant setting – Sanyo PLC WTC500L User Manual
Page 57
57
Setting
Press the SELECT button at
Power management and this
dialog box appears. Use the
Point
7 8
buttons to choose
one of the three options.
Press the Point
d
button to
select the timer, and then use
the Point
7 8
buttons to set
timer.
Power management
Select one of the following options:
Ready ................. When the lamp has been fully cooled
down, the POWER indicator changes to fast
blinking. In this condition, the projection
lamp can be turned on if the input signal
is reconnected or any button on the top
control or remote control is pressed.
Shut down ......... When the lamp has been fully cooled down,
the power will be turned off.
Off ..................... Power management function is off.
On start
When this function is set to “On,” the projector will be
automatically turned on just by connecting the AC power cord
to a wall outlet.
✔
Note:
• Be sure to turn off the projector properly (see “Turning
Off the Projector” on page 25). If the projector is turned
off in the incorrect sequence, the On start function does
not work properly.
•
When the Standby mode is set to “Eco“ in the Setting, the On
start funcion is disabled. (p.56)
✔
Note:
• Factory default is “Ready: 5 min.”
Slant
This function is used to set the cooling fans’ operation to the
projector’s setting environment. Set this function properly in
accordance with the projector’s installation method. Otherwise,
the cooling fans will not work properly and that causes
malfunctions of the projector and decreases the lamp life.
Select the projector’s installation condition from the following
options:
Off .....When using the projector within the range of the upward/
downward inclination of
±
70º and +110º~ +180
º,
-110
º
~
-180º to the horizontal plane.
L1 ......When using the projector within the range of the upward/
downward inclination of +70º~+110
º
to the horizontal
plane.
L2 ......When using the projector within the range of the upward/
downward inclination of -70º~ -110
º
to the horizontal
plane.
L3 ......When using the projector within the range of the upward/
downward inclination of
±
70º to the horizontal plane
and
the ceiling function is set to “On”.
L4 ......When using the projector within the range of the upward/
downward inclination of +110º~+180
º,
-110
º
~ -180º to the
horizontal plane and the ceiling function is set to “Off”.
+70°
+110°
-70°
-110°
+180°
-180°
+0°
-0°
UP
UP
UP
UP
UP
UP
UP
UP
L1
L2
“L4” at Ceiling “Off”
“Off” at Ceiling “On”
“L3” at Ceiling “On”
“Off” at Ceiling “Off”
Slant setting