beautypg.com

Precautions – Sharp AR-810 User Manual

Page 11

background image

1

2

3

4

5

6

7

8

9

10

11

12

7

PRECAUTIONS

1. Installation

1

The AR-651/810 should be installed by a qualified service technician.

Note: The packing material should be disposed of properly.

2

To obtain the best possible results, this copier should be used in conjunction with a

dedicated AC power line with the following ratings.

115V— 60Hz,20A

Notes:

1. The use of other appliances or other equipment on the same line as this copier may adversely

affect performance and copy quality.

2. Be sure to use a 3-conductor, grounded wall outlet.
3. In areas where a 2-pin plug is used, the copier must be grounded for safety.

Never ground it to a gas pipe, a water pipe, or any other object not suitable for grounding.

3

After a suitable place has been selected for installation of the AR-651/810, please do

not change it. Avoid excessive heat, dust, vibration and direct sunlight. Also, provide

proper ventilation as the copier emits a small amount of ozone.

Notes:

1. The recommended environmental range for use is as follows:

• Temperature:

10~30°C/50~86°F

• Humidity:

20~85% RH (Non condensing)

2. To insure optimal operation, allow clearances of at least 31.5" on the left, 31.5" on the right and 3.9"

behind (refer to the illustration below).

The socket outlet should be near the equipment and be easily accessible.

3.9"

31.5"

31.5"

A small amount of ozone is produced within the printer during operation. The emission level is
insufficient to cause any health hazard.

Note:

The present recommended long term exposure limit for ozone is 0.1 ppm (0.2 mg/m

3

) calculated as

an 8 hr. time-weighted average concentration.
However, since the small amount that is emitted may have an objectionable odor, it is advisable to
place the copier in a ventilated area.