4. status indications – Sony PFV-L10 User Manual
Page 9

1-3 (E)
PFV-L10
1-4. Status Indications
The status indicators A and B on the front panel indicate the present condition of the PFV-L10.
Power Supply Unit
Indicator
Condition
Indicator A
Indicator B
One unit
Lights in green
_
Normal operation
Blinks in red
_
.
The cooling fan has stopped rotating.
.
The total current for the plug-in boards has
exceeded 13 A.
.
The temperature inside the power supply unit A
has risen over a specified level.
Two units
Lights in green
Lights in green
Normal operation
Blinks in red
Lights in green
Power supply unit A
.
The power switch is set to OFF.
.
The AC cable has come off.
. +
5 V voltage is not output.
.
The temperature inside the power supply unit has
risen over a specified level.
Power supply unit B: Normal operation
Lights in green
Blinks in red
Power supply unit A: Normal operation
Power supply unit B
.
The power switch is set to OFF.
.
The AC cable has come off.
. +
5 V voltage is not output.
.
The temperature inside the power supply unit has
risen over a specified level.
Blinks in red
Blinks in red
.
The cooling fan has stopped rotating.
.
The total current for the plug-in boards has
exceeded 13 A.
.
The temperature in the power supply block (power
supply units A and B) has risen over a specified level.
1-4. Status Indications
Power supply unit A
Status indicator A
Status indicator B
Power supply unit B