Instructions for the installer

30

5.3

Regulation for G25/25 mbar

The hob has been inspected for G25 (2L) at a pressure of 25 mbar. To
allow the unit to work with this type of gas, perform the same operations
described in paragraph “5.2 Regulation for LPG”, but choose the nozzles
and regulate the primary air for natural gas, as shown in the following
table and in paragraph "5.4 Regulation of primary air”. After the
regulations have been carried out, restore the seals with sealing wax or
equivalent material.


Burner

Rated heating

capacity

(kW)

G25 25 mbar

Nozzle diameter

1/100 mm

Reduced flowrate

(W)

Auxiliary (1)

1.05

76

380

Semi-rapid (2)

1.65

98

380

Rapid (3)

3.1

130

750

internal (4)

1.05

76

380

Double crown

internal (4)

3.9

150

1200

5.4

Regulation of primary air

Referred to distance “X” in mm.

BURNER

G25

25 mbar

G30/G31

30/30 mbar

Auxiliary

(1)

1.5

2.0

Semi-rapid

(2)

1.5

2.0

Rapid

(3)

2.0

9.0

internal (4)

3.0

6.0

Double crown

external (4)

3.0

10.0

(*) For burner reference numbers, see page 32.