beautypg.com

Appendix, I 2 of 5 modulo 10 check, Itf14/ean13 conversion – Symbol Technologies LS 1000 User Manual

Page 57

background image

4-23

LS 1000 Product Reference Guide: Chapter 4, Programming the LS 1004

I 2 of 5 Modulo 10 Check

When enabled, this parameter checks the integrity of a Interleaved 2 of 5 symbol to
ensure it complies with specific algorithms.

ITF14/EAN13 Conversion

This feature converts a 14-character I 2 of 5 code into EAN13, and transmits to the host
as EAN13. In order to accomplish this, the I 2 of 5 code must be enabled, one length
(either LENGTH 1 or LENGTH 2) must be set to 14, the code must have a leading zero
and proper trailing check digit.

I 2of 5 Modulo 10

Check Digit Enable

I 2of 5 Modulo 10

Check Digit Disable

ITF-14/EAN-13 Conver-

sion

ITF-14/EAN-13 Conversion

Disable

coverBook Page 23 Monday, December 1, 1997 2:19 PM