beautypg.com

18 line - hot line dial string, 19 line - intrusion allowed – Siemens OPTIPOINT 410 S V6.0 User Manual

Page 74

background image

xml_03.fm

A31003-J4260-M101-2-76A9, 03-2007
XML Configuration Management, Administrator Manual

3-51

XML Overview

Administration Tags

3.3.13.18

Line – Hot line dial string

3.3.13.19

Line – Intrusion allowed

Parameter

line-hld

WEB

Index

1 to 18

Normal function keys 1 to 18, opti-
Point 410 advance

Index

101 to 116

Normal function keys 1 to 16,

key

module 1

Index

201 to 216

Normal function keys 1 to 16,

key

module 2

Index

301 to 313

Normal function keys 1 to 13,

self

labeling key module 1

Index

401 to 413

Normal function keys 1 to 13,

self

labeling key module 2

Value

AaBbcde123456

Target phone URI for hot line (al-
phanumeric)

Example

123456789

Notes

Only possible if the key has been configured with "line"

Parameter

line-int-allow

WEB

Index

1 to 18

Normal function keys 1 to 18, opti-
Point 410 advance

Index

101 to 116

Normal function keys 1 to 16,

key

module 1

Index

201 to 216

Normal function keys 1 to 16,

key

module 2

Index

301 to 313

Normal function keys 1 to 13,

self

labeling key module 1

Index

401 to 413

Normal function keys 1 to 13,

self

labeling key module 2

Value

true, false

Show secondary or group conver-
sation on or off

Example

true

Notes

Only possible if the key has been configured with "line"