beautypg.com

3 administration tags, 1 system tag, 1 system config – Siemens OPTIPOINT 410 S V6.0 User Manual

Page 27: 2 device config, 3 administration tags -4, 1 system tag -4, 1 system config -4 3.3.1.2 device config -4

background image

XML Overview

A31003-J4260-M101-2-76A9, 03-2007

3-4

XML Configuration Management, Administrator Manual

xml_03.fm

Administration Tags

3.3

Administration Tags

The sequence of tags described in this section is based on the sequence in WBM and its dia-
logs.

3.3.1

System Tag

Determines whether there is a system-wide or device-specific configuration and whether the
file content was modified - in this case via the "Value" field. Every time the content of the "Val-
ue" field does not match the previous entry, the phone will read all items in the file. If the content
is unchanged, no action is taken.

3.3.1.1

System config

3.3.1.2

Device config

Parameter

system-config-version

Start of system-wide configuration
file

Index

Value

2005.09.20 09:54 GMT

Date and time of modification

Example

2005.09.20 09:54 GMT

Make sure you enter spaces be-
fore and after the "=" sign.

Notes

Only applies to system-wide configuration - excludes device configuration

Parameter

device-config-version

Start of device-specific configura-
tion file

Index

Value

2005.09.20 09:54 GMT

Date and time of modification

Example

2005.09.20 09:54 GMT

Make sure you enter spaces be-
fore and after the "=" sign.

Notes

Only applies to device-specific configuration - excludes system configuration.