XML Overview

A31003-J4260-M101-2-76A9, 03-2007

3-14

XML Configuration Management, Administrator Manual

xml_03.fm

Administration Tags

3.3.3.16

SIP transport

3.3.3.17

SIP server type

3.3.3.18

SIP session timer enabled

Parameter

sip-transport

WEB

Index

Value

0, 1, 2

Transport protocol
0=UDP
1=TCP
2=TLS

Example

0

Notes

e164, must be configured in the HiPath 8000 (SMC) Config Portal

Parameter

server-type

WEB

Index

Value

1, 2, 3, 4

SIP server type
1=HiQ8000
2=Broadsoft
3=Sylantro
4=other

Example

2

Notes

e164

Parameter

session-timer

WEB

Index

Value

true, false

Session timer on or off

Example

false

Notes

e164