Curing
The bonded joint can be worked mechanically after 2 hours at
room temperature; a waiting period of 15 minutes is sufficient if an
infra-red radiator is used with a temperature of 60
C. The infra-
red radiator should be placed at a distance of ca. 30 cm from the
bond. Object temperature 60
C.
Cleaning
Fresh, non-cured material (e. g. for cleaning tools, cleaning
contaminations on the substrates etc.) may first be removed dry
and then cleaned off with a suitable solvent (e.g. acetone, ethyl
acetate, Cleaner-A, Cleaner-D). Cured adhesive can only be
removed mechanically.