beautypg.com

2 burner and nozzle characteristics table, 3 arrangement of the burners on the hob, Instructions for the installer – Smeg CE92GPX User Manual

Page 30

background image

Instructions for the installer

63

17.2 Burner and nozzle characteristics table

Burner

Rated heating

capacity (kW)

LPG – G30/G31 28/37 mbar

Nozzle

diameter 1/

100 mm

By-pass

1/100

mm

Reduced

flowrate

(W)

Flowrate

g/h G30

Flowrate

g/h G31

Auxiliary

1.05

50

30

400

76

75

Semi rapid

1.8

65

33

500

130

128

Rapid

3.0

85

45

800

218

214

Triple crown

4.0

100

65

1600

291

286

Burner

Rated heating

capacity (kW)

NATURAL GAS – G20/G25 20/25 mbar

Nozzle diameter

1/100 mm

Reduced flowrate

(W)

Auxiliary

1.0

72 (X)

400

Semi rapid

1.8

97 (Z)

500

Rapid

3.0

115 (Y)

800

Triple crown

4.0

135 (K)

1600

17.3 Arrangement of the burners on the hob

BURNERS

1. Auxiliary
2. Semi rapid
3. Rapid
4. Triple crown

min. and max. Ø (in cm)

12 - 14
16 - 24
18 - 26
18 - 26