Selecting a Site

TigerAccess 10/100 units can be mounted in a standard 19-inch
equipment rack or on a flat surface. Be sure to follow the guidelines below
when choosing a location.

• The site should:

- restrict access to authorized service personnel in accordance with IEC

60950-1. A restricted access location is one where access is secure and
limited to service personnel who have a special key, or other means of
security.

- be at the center of all the devices you want to link and near a power

outlet.

- be able to maintain its temperature within 0 to 50 °C (32 to 122 °F) and

its humidity within 5% to 95%, non-condensing

- provide adequate space (approximately five centimeters or two inches)

on all sides for proper air flow

- be accessible for installing, cabling and maintaining the devices
- allow the status LEDs to be clearly visible

• Make sure twisted-pair cable is always routed away from power lines,

fluorescent lighting fixtures and other sources of electrical interference,
such as radios and transmitters.

• Make sure that the unit is connected to a separate grounded power outlet

within 2 m (6.6 feet) of each device and is powered from an independent
circuit breaker. As with any equipment, using a filter or surge suppressor