6 connection, 1 overview of connection, Connection – Siemens Plant Central Clock TC100 User Manual
Page 34: Overview of connection, Connection (chapter 6)
6-3
©
Siemens AG 2010 All Rights Reserved
SICLOCK
®
TC100 Operating Instructions
Connection
6
6.1
Overview of connection
Ensure that the installation complies with the following conditions:
•
The device may only be connected to 24 VDC power supply systems which
meet the requirements of a safe extra-low voltage with protective separation
according to SELV. The conductor cross-section selected must be large
enough so that if there is a short circuit in the SICLOCK TC100 no damage
can be caused by an overheated cable. For the conductor cross-section, see
Connecting the power supply (Chapter 6.2).
•
Avoid extreme ambient conditions as far as possible.
•
Protect the device against dust, moisture, heat and severe vibrations.
•
Do not place the device in direct sunlight.
•
Install the device in such a way that it cannot pose any danger, for example by
falling down.
•
Do not cover the ventilation slots
•
Permissible mounting position (Chapter 4.4.2).
Notice
Only connect peripheral devices suitable for an industrial environment.
Caution
Strictly adhere to the specifications for peripheral equipment.