Fi100-40 fluxgate interface, Rf45x rudder feedback unit, 5 fi100-40 f – Simrad ROBERTSON AP45 User Manual
Page 43: Luxgate, Nterface, Dimensions, 6 rf45x r, Udder, Eedback
![background image](/manuals/145039/43/background.png)
Robertson AP45 Autopilot
Technical specifications
Simrad Robertson AS
Egersund - Norway
Page 4-5
Dimensions:................................................See Fig. 4-5.
Cable length: ..............................................2 m (with plug)
Ambient temperature, storage:............–25 - +70°C
operation: .......–10 - +55°C
Input signal: ...............................................sine/cosine
Output signal:.............................................sine/cosine ±2V DC at +2.5V reference
8
9
(
3
.5
")
47 (1.85")
3.5 (0.14")
160 (6.3")
144 (5.67")
3
4
(
1
.3
4
")
148 (5.83")
2
5
(
0
.9
8
")
Fig. 4-5
FI100-40 Fluxgate Interface - dimensions
Dimensions: ................................................See Fig. 4-6.
Protection:...................................................IP56
Ambient temperature: ...............................–10 - +55°C
Operating voltage:......................................12V DC (autopilot supplied)
Frequency output, Feedback: ....................3400Hz (midship reference)
Port: +20Hz/degree, stbd: -20Hz/degree
Current output, Indicator..........................0.1mA - 1.1mA
Capacity: .....................................................5 indicators in series
Rudder angle: .............................................
±
45°
Cable length:...............................................2 m (6 ft)
Fig. 4-6
RF45X Rudder Feedback - dimensions
FI100-40 Fluxgate
Interface
RF45X Rudder
Feedback Unit