beautypg.com

SMC Networks System 5000 User Manual

Page 36

background image

April 17, 2000

Man ual Versio n 1.0

4.12

NOTE:

It is absolutely critical to set the upper and lower limits correctly before
calibrating a rotary slide adjust system. The calibration process uses this
information to map the turns from the dual resolver into the measurement
space of the slide. If the upper and lower limits are not set correctly, the
system may fail to calibrate!

NOTE:

It is very important to make as accurate a measurement as possible for the
Upper and Lower Calibration Points. If these measurements are wrong, then
the slide position reported by the system will also be wrong!

screen of Figure 4.3.

b) Press the “CALIBRATE SLIDE” softkey in the slide configuration screen of Figure 4.3.

c) A screen will appear with a warning that calibrating the slide should not be undertaken without

first reading this manual. Press the “CONTINUE SLIDE CAL.” softkey to continue the
calibration process or “EXIT” to return to slide configuration.

d) Now the screen should warn that the upper and lower limits must be set correctly before

continuing slide calibration. See step “a” above. Press the “CONTINUE SLIDE CAL.” softkey
to continue the calibration process or “EXIT” to return to slide configuration.

e) The number of resolver turns must now be set. Use table 4.3 to find the correct number of turns

for the resolver used in the system.

Table 4.3: Resolver Turns

Manufacturer

Model #

Turns

AMCI

HTT-20-100

100

AMCI

HTT-20-180

180

Patriot (GEMCO)

SD-0410900

64

Patriot (GEMCO)

SD-0410901

128

Press the “CONTINUE SLIDE CAL.” softkey to continue the calibration process or “EXIT” to
return to slide configuration.

f) The system now needs an upper calibration point. With the press as near as possible to bottom

dead center (180 degrees), use the “JOG UP” and “JOG DOWN” softkeys to take the slide near
the top of the adjustment range. The slide should be slightly lower than the upper limit that was
entered on the slide configuration screen. Take the measurement of the shut height in this
position as carefully and accurately as possible and without moving the slide enter the number
as requested on the screen.