beautypg.com

J9 port - communication port - not used, J10 socket - not used, J11 port - communication port - not used – State Industries GP650YTPDT User Manual

Page 39: J13 socket - blower speed control (vfd), J15 socket - not used, S1 dip switch, On closed off open, Ccb (cont), Op en 1 2 3 4, No vent spare

background image

ULTRA HIGH EFFICIENCY POWER VENT/POWER DIRECT VENT - SERVICE MANUAL

Technical Literature Department

38 of 52

Ashland City, TN © 2008

Servicing should only be performed by a Qualified Service Agent

CCB (CONT)

J7 Socket - Temperature Probe/ECO (immersion probe - top of the water heater)

J9 Port - Communication Port - Not Used
J10 Socket - Not Used
J11 Port - Communication Port - Not Used
J13 Socket - Blower Speed Control (VFD)

J15 Socket - Not Used
J16 Port - Communication Port - UIM Display (user interface module)
S1 Dip Switch

The S1 dip switches are configured from the factory and should not be changed. The
illustration below shows the 4 dip switches with labeling. Dip switches are toggle type micro
switches. Flipping a dip switch towards “Open” would be the same as “Off.” Flipping a dip
switch the other way (towards the switch numbers) is the same as “On.”

Dip switch #1 is used to configure the water heater to declare a fault condition and lock out
after one or three failed trials for ignition. The factory setting is “on” for three trials.

Dip switches #2 and #3 are used when this control system is installed on other products.
The factory setting for these two dip switches is “on.”

Dip switch #4 is a spare, configuration does not matter.

PIN #

DESCRIPTION

1

ECO (energy cut out) 24 VAC out (red wire)

2

Upper temperature probe (thermistor) +5.0 VDC (black wire)

3

Upper temperature probe (thermistor) -5.0 VDC (black wire)

4

ECO (energy cut out) 24 VAC return (red wire)

PIN #

DESCRIPTION

1

Not used

2

Not used

3

To Blower low voltage PWM plug (see page 10) - pin #5 (white w/grn stripe)

4

Not used

5

Not used

6

Not used

7

To Blower low voltage PWM plug (see page 10) - pin #4 (white w/blue stripe)

8

To Blower low voltage PWM plug (see page 10) - pin #1 (white w/brn stripe)

OP
EN

1 2 3 4

1 Retry

Use Yes

Type Tstat

Spare

Ext

Input

3

Retries

No

Vent

Spare

ON

CLOSED

OFF

OPEN