beautypg.com

J1 socket - transformer, J2 socket - 120 vac to blower, J3 socket - 120 vac power supply – State Industries GP650YTPDT User Manual

Page 38: J4 flame sensor - male spade connector, Ccb (cont)

background image

Technical Literature Department

37 of 52

Ashland City, TN © 2008

Servicing should only be performed by a Qualified Service Agent

ULTRA HIGH EFFICIENCY POWER VENT/POWER DIRECT VENT - SERVICE MANUAL

CCB (CONT)

J1 Socket - Transformer

J2 Socket - 120 VAC To Blower

J3 Socket - 120 VAC Power Supply

J4 Flame Sensor - Male Spade Connector
J5 Socket
- Igniter 120 VAC HSI (hot surface igniter - Silicon Carbide)

J6 Socket - Gas Valve, Pressure Switches, Enable/Disable Circuit

PIN #

DESCRIPTION

1

120 VAC hot to transformer

2

Not used

3

120 VAC neutral to transformer

4

24 VAC out from transformer

5

24 VAC out from transformer

PIN #

DESCRIPTION

1

120 VAC hot to blower

2

120 VAC neutral to blower

3

Not used

4

Not used

PIN #

DESCRIPTION

1

120 VAC hot

2

Earth Ground

3

120 VAC neutral

PIN #

DESCRIPTION

1

120 VAC hot

2

120 VAC neutral

PIN #

DESCRIPTION

1

Not used

2

Gas valve - 24 VAC

3

Not used

4

Blocked Intake air pressure switch

5

Blocked Exhaust air pressure switch

6

Blower Prover air pressure switch

7

Blower Prover air pressure switch

8

Enable/disable external control circuit - jumper installed from factory

9

Not used

10

Blocked Exhaust air pressure switch

11

Enable/disable external control circuit - jumper installed from factory

12

Not used

13

Not used

14

Blocked Intake air pressure switch

15

Gas valve - 24 VAC