J1 socket - transformer, J2 socket - 120 vac to blower, J3 socket - 120 vac power supply – State Industries GP650YTPDT User Manual
Page 38: J4 flame sensor - male spade connector, Ccb (cont)
Technical Literature Department
37 of 52
Ashland City, TN © 2008
Servicing should only be performed by a Qualified Service Agent
ULTRA HIGH EFFICIENCY POWER VENT/POWER DIRECT VENT - SERVICE MANUAL
CCB (CONT)
J1 Socket - Transformer
J2 Socket - 120 VAC To Blower
J3 Socket - 120 VAC Power Supply
J4 Flame Sensor - Male Spade Connector
J5 Socket - Igniter 120 VAC HSI (hot surface igniter - Silicon Carbide)
J6 Socket - Gas Valve, Pressure Switches, Enable/Disable Circuit
PIN #
DESCRIPTION
1
120 VAC hot to transformer
2
Not used
3
120 VAC neutral to transformer
4
24 VAC out from transformer
5
24 VAC out from transformer
PIN #
DESCRIPTION
1
120 VAC hot to blower
2
120 VAC neutral to blower
3
Not used
4
Not used
PIN #
DESCRIPTION
1
120 VAC hot
2
Earth Ground
3
120 VAC neutral
PIN #
DESCRIPTION
1
120 VAC hot
2
120 VAC neutral
PIN #
DESCRIPTION
1
Not used
2
Gas valve - 24 VAC
3
Not used
4
Blocked Intake air pressure switch
5
Blocked Exhaust air pressure switch
6
Blower Prover air pressure switch
7
Blower Prover air pressure switch
8
Enable/disable external control circuit - jumper installed from factory
9
Not used
10
Blocked Exhaust air pressure switch
11
Enable/disable external control circuit - jumper installed from factory
12
Not used
13
Not used
14
Blocked Intake air pressure switch
15