Resetting the RXT150 with the Serial Interface
Before You Begin
Before using the serial interface, make sure that:
• You have a properly configured terminal emulator, such as TeraTerm.
(HyperTerminal is not recommended for use with the RXT-150.)
• You have a standard DB9 serial cable.
• The terminal emulation settings are set to:
• 115200 bps
• 8 data bits
• No parity
• 1 stop bit
• No flow control
Resetting the RXT150
1. Connect a serial cable from the host to the RXT150.
2. Open TeraTerm, or a similar terminal emulation program.
(HyperTerminal is not recommended for use with the RXT150.
3. Press the Enter key on your keyboard to display a command prompt.
4. Type
cnDiagnosticShell
, then press the Enter key on your keyboard. The
RXT Drive Diagnostics Main Menu (Figure 2-10) displays.
5. Type
6
, then Enter; a prompt appears, asking you to confirm the reset.
6. To confirm the reset, type
Y
, then Enter. In less than 30 seconds, the RXT150
reboots; it should come to ready mode again in the normal time frame of 20
seconds to two minutes.
To escape the reset process, type
N
, then Enter.