Symbol Technologies DS6708 User Manual
Page 338
B - 6
DS6708 Digital Scanner Product Reference Guide
PDF417, Micro
PDF417
0
Reader set to conform to protocol defined in 1994 PDF417 symbology
specifications. Note: When this option is transmitted, the receiver cannot
reliably determine whether ECIs have been invoked or whether data byte
92
DEC
has been doubled in transmission.
1
Reader set to follow the ECI protocol (Extended Channel Interpretation). All
data characters 92
DEC
are doubled.
2
Reader set for Basic Channel operation (no escape character transmission
protocol). Data characters 92
DEC
are not doubled. Note: When decoders are
set to this mode, unbuffered Macro symbols and symbols requiring the
decoder to convey ECI escape sequences cannot be transmitted.
3
The bar code contains a UCC/EAN-128 symbol, and the first codeword is
903-907, 912, 914, 915.
4
The bar code contains a UCC/EAN-128 symbol, and the first codeword is
in the range 908-909.
5
The bar code contains a UCC/EAN-128 symbol, and the first codeword is
in the range 910-911.
Example: A PDF417 bar code ABCD, with no transmission protocol enabled, is transmitted as
]L2ABCD.
Data Matrix
0
ECC 000-140, not supported.
1
ECC 200.
2
ECC 200, FNC1 in first or fifth position.
3
ECC 200, FNC1 in second or sixth position.
4
ECC 200, ECI protocol implemented.
5
ECC 200, FNC1 in first or fifth position, ECI protocol implemented.
6
ECC 200, FNC1 in second or sixth position, ECI protocol implemented.
MaxiCode
0
Symbol in Mode 4 or 5.
1
Symbol in Mode 2 or 3.
2
Symbol in Mode 4 or 5, ECI protocol implemented.
3
Symbol in Mode 2 or 3, ECI protocol implemented in secondary message.
Table B-4
Modifier Characters (Continued)
Code Type
Option Value
Option