beautypg.com

4 regulation for natural gas, Instructions for the installer – Smeg AP64S3 User Manual

Page 11

background image

Instructions for the installer

34

5.4

Regulation for natural gas

The hob has been inspected for G20 (2H) natural gas at a pressure of

20 mbar. To allow the unit to work with this type of gas, perform the
same operations described in paragraph “5.3

Regulation for LPG”, but

choose the nozzles and regulate the primary air for natural gas, as
shown in the following table and in paragraph “5.5

Regulation of

primary air”. After the regulations have been carried out, restore the
seals with sealing wax or equivalent material.

Burner

Rated

heating

capacity

Natural gas – G20 20 mbar

Nozzle diameter

1/100 mm

Reduced flowrate

(W)

Auxiliary

1.05

73

400

Semirapid

1.8

93

450

Rapid

2.55

115

750

Rapid large

3.1

128

750

Fish pan

2.9

123

950

Ultra rapid

4.0

142

1400