Beeper definitions, Beeper definitions -4, Table 2-1. beeper definitions – Symbol Technologies DS 6608 User Manual
Page 30

DS 6608 Product Reference Guide
2-4
Beeper Definitions
The digital scanner issues different beep sequences and patterns to indicate status.
defines beep sequences that occur
during both normal scanning and while programming the digital scanner.
Table 2-1. Beeper Definitions
Beeper Sequence
Indication
Standard Use
Low/medium/high beeps
Power up.
Short high beep
A bar code symbol was decoded (if decode beeper is enabled).
4 long low beeps
A transmission error was detected in a scanned symbol. The data is ignored. This occurs if the digital scanner is not
properly configured. Check option setting.
5 low beeps
Conversion or format error.
Lo/hi/lo beeps
ADF transmit error. See
Chapter 15, Advanced Data Formatting
Hi/hi/hi/lo beeps
RS-232 receive error.
Parameter Menu Scanning
Short high beep
Correct entry scanned or correct menu sequence performed.
Lo/hi beeps
Input error; incorrect bar code, programming sequence, or Cancel scanned;
remain in ADF program mode.
Hi/lo beeps
Keyboard parameter selected. Enter value using numeric bar codes.
Hi/lo/hi/lo beeps
Successful program exit with change in parameter setting.
Low/hi/low/hi beeps
Out of host parameter storage space. Scan
Set Default Parameter on page 4-5
Code 39 Buffering
Hi/lo beeps
New Code 39 data was entered into the buffer.
3 long high beeps
Code 39 buffer is full.
Lo/hi/lo beeps
The Code 39 buffer was erased or there was an attempt to clear or transmit an empty buffer.
Lo/hi beeps
A successful transmission of buffered data.
Macro PDF
2 long low beeps
File ID error. A bar code not in the current MPDF sequence was scanned.
3 long low beeps
Out of memory. There is not enough buffer space to store the current MPDF symbol.
4 long low beeps
Bad symbology. Scanned a 1D or 2D bar code in a MPDF sequence, a duplicate MPDF label, a label in an incorrect order,
or trying to transmit an empty or illegal MPDF field.
5 long low beeps
Flushing MPDF buffer.
Fast warble beep
Aborting MPDF sequence.
Lo/Hi beeps
Flushing an already empty MPDF buffer.
ADF Programming: Normal Data Entry. Duration of tones are short.
Hi/Lo beeps
Enter another digit. Add leading zeros to the front if necessary.
Lo/Lo beeps
Enter another alphabetic character or scan the End of Message bar code.
Hi/Hi beeps
Enter another criterion or action, or scan the Save Rule bar code.
Hi/Lo/Hi/Lo beeps
Rule saved. Rule entry mode exited.
Hi/Lo/Lo beeps
All criteria or actions cleared for current rule, continue entering rule.