beautypg.com

Items related to the pull down control (a01~), A-43 – Sony HDW-F500 User Manual

Page 171

background image

Appendix

A-43

Appendix

Items Related to the Pull Down Control (A01~)

The values enclosed in a box are the factory settings.

Item number

Settable range

Function

Item

A01

PD TIME CODE
DISPLAY

[off]

on

Sets whether or not to display the pull down time code on
the time code display area.
off: Does not display the pull down time code.
on: Displays the pull down time code.

A02

PD PRESET
FRAME MODE

[24 FRAME MODE]

30 FRAME MODE

Selects the time code to be preset. The A frame of the
pulldown sequence can be preset.
24 FRAME MODE: The 24 frames time code is preset.
30 FRAME MODE: The 30 frames time code is preset.

A03

PD
SUPERIMPOSED
CHARACTER

[off]

on

Specifies whether or not to superimpose time data and
operating status information on the signal output from the
PULL DOWN OUT connector.
off: No information is superimposed.
on: Information is superimposed.

A04

PD DF/NDF
SELECT

[drop frame]

non-drop frame
auto

Selects the running mode for the pull down time code to be
preset.
drop frame: Drop frame mode
non-drop frame: Non-drop frame mode
auto: The unit switches the running mode (DF/NDF)

automatically according to the frame frequency of the
unit. When the frame frequency is 23.976 Hz, the unit
switches to the drop frame mode and switches to the
non-drop frame mode when it is 24 Hz.