6
.6
4
Pull the imaging unit out of the machine using the handle on its
bottom.
5
Extend the top handle on the imaging unit and then use it to pull the
imaging unit out of the machine completely.
6
Take a new imaging unit out of its package. Remove the protective
devices on both sides of the imaging unit and the paper protecting
the surface of the imaging unit.
Caution
• Don’t use sharp objects, such as a knife or scissors, to open
the imaging unit package. You could damage the surface of
the imaging unit.
• Be careful not to scratch the surface of the imaging unit.
• To prevent damage, do not expose the imaging unit to light for
more than a few minutes. Cover it with a piece of paper to
protect it if necessary.
7
Holding the handles on the new imaging unit, push the imaging unit
until it sounds 'click' in to the machine.
8
Remove four dummy caps which are on the toner cartridge
entrances of the imaging unit. When you remove the dummy cap
from the cartridge, lift the handle up and pull it out.
Caution
If you force too much to the dummy caps, it may cause problem.
9
Insert the toner cartridges and waste toner container back into their
corresponding slots until they click into place. And rotate the toner
cartridges clockwise.
10
Close the front cover firmly.