Replacing the imaging unit – Samsung CLP-350 User Manual
Page 37
6.5
6
Remove the cartridge cap.
Note
If toner gets on your clothing, wipe it off with a dry cloth and
wash it in cold water. Hot water sets toner into fabric.
7
Grasp the toner cartridge and align it with the corresponding slot
inside the machine. Insert it back into its slot until it clicks into place,
and rotate the toner cartridge clockwise.
8
Close the front cover. Make sure that the cover is securely latched,
and then turn the machine on.
Caution
If the front cover is not completely closed, the macnine will not
operate. Please make sure all toner cartridges are installed
properly. If any toner cartridge is installed improperly, the front
cover do not close.
Note
• Each LED blinks red in a repeated order. Wait for about 1.5
minutes for your machine to get ready.
• When printing text at 5% coverage, you can expect a print
cartridge life of about 4,000 pages for black and white printing
and 2,000 pages for color printing. However, the print
cartridge that is shipped with the printer prints 3,000 pages for
black and white, 1,500 pages for colors.
Replacing the Imaging Unit
The life of the imaging unit is approximately 20,000 pages for black or
46,000 images for printing. When the life span of the imaging unit has
expired, the Smart Panel program window appears on the computer,
indicating the imaging unit needs to be replaced. Otherwise your machine
stops printing.
To replace the imaging unit:
1
Turn the machine off, then wait a few minutes for the machine to
cool.
2
Open the front cover.
3
Rotate all toner cartridges counter-clockwise and pull them out.
Remove waste toner container from the machine.