Instructions for the installer

The standard cable is of the three-core
3 x 2.5 mm

2

H07RN-F type.

For operation from a 400V3N

power

supply, replace the standard cable with
one of the H07RN-F type. The cross
section of the leads of the latter cable
must not be less than 1.5 mm

2

(5 x 1.5

mm

2

); the ground (yellow-green) of the

termination to be linked up to the oven
must be at least 20 mm longer.


If connecting by plug and socket, make sure to use a 25 Amp. three-core
plug or a 16 Amp. five-core plug in case of operation at 400V3N

. Make

sure that plug and wall socket are of the same type and are in conformity
with regulations in force. Also check that the power supply line is
provided with adequate earthing. Avoid using adapters or shunters.


In case of permanent connection, ensure that power cable is equipped
with an easily accessible omnipolar switch fitted in proximity to the
apparatus and with a gap between contacts equal to or greater than
3 mm.



2.1.1 Safety

thermostat

The oven is fitted with a safety device which trips in case of serious
malfunction. To reset, contact the nearest servicing centre.

The manufacturer declines all responsibility for damage to persons
or things caused by non-observance of the above prescriptions or by
interference with any part of the oven.








23